Sign In | Join Free | My chinacsw.com
China Shanghai Berry Electronic Tech Co., Ltd. logo
Shanghai Berry Electronic Tech Co., Ltd.
LOVE LIFE ALWAYS
Verified Supplier

3 Years

Home > Patient Monitor Module >

DC 3.6V to 6.0V OEM Module Spo2 Module ECG Module

Shanghai Berry Electronic Tech Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

DC 3.6V to 6.0V OEM Module Spo2 Module ECG Module

  • 1
  • 2

Brand Name : BERRY

Model Number : ECG007

Place of Origin : Shanghai

MOQ : 100PCS

Price : Negotiation

Payment Terms : T/T

Delivery Time : 15 DAYS

Packaging Details : 100*80*25mm

Type : ECG007

Name : ECG/RESP/TEMP Module

Package : standard

ECG Full lead : I,II,III ,aVL, aVR, aVF, and V1,V2,V3,V4,V5,V6

Warranty : 1 year

Weight : 60g

Work current : <100mA

Power supply voltage : DC from 3.6 V to 6.0 V

Working temperature : Scope: 20-50℃

size : 100*80*25mm

Gain : 5mm/mV,10mm/mV,20mm/mV and 40mm/mV

Scanning speed : Changeable with three grades 12.5mm/s,25mm/s and 50mm/s

elivery time Mass production : about 15 days (2000pieces)

OEM : about 25 days

RESP RATE RANGE : 3-150bpm

Contact Now

ECG007oem module spo2 oem module ECG module

Technical Specifications:

1. Principle of Operation: Non-dispersive infrared (NDIR)
2. Initialization Time: Capnogram displayed in less than 20 seconds Reaching full specifications
within 2 minutes.
3. Co2 Measure Range: 0 - 150 mmHg; 0 - 19.7%; 0 - 20kPa
Co2 Measure Resolution: 0.1mmHg
Co2 Accuracy: 0-10mmHg ± 2mmHg; 41-70mmHg ± 5% of reading;
71-100mmHg ± 8% of reading; 101-150mmHg ± 10% of reading
4. Calibration: No routine user calibration required, The mainstream sensor an airway adapter
5. Zero is required when changing to a different airway adapter
6. Compensation: Barometer Pressure 450 - 850 mmHg.
7. Operator selectable O2, N2O, He compensation.
8. Data Interface: Rs232, 19200 baud rate, standard N-8-1.
9. Regulatory: Designed to comply YY0601 and ISO21647

Introduction

The YS3000 is a stand-alone external pulse oximetry module that can be externally connected to a multiparameter monitor,or a hand-held oximeter and other devices that require measurement of oxygen saturation. Connecting to your device via a simple TLL interface, the module can measure blood oxygen saturation accurately with a SpO2 sensor.

Feature-ECG007 Module

► Small volume,flexible installment mode,high reliable and accurate test.
► Excellent reliability and clinical monitoring fuction.
► It has implemented the monitor of 7 channel ECG, 1channel RESP and2channels temp on the same time.
► In accordance with function safety design of CE requirements.
► In accordance with all the ecg/temp monitoring work
► Suitable for adult,pediatric and neonate.
► Single power 5V work,low power consumption design.

DC 3.6V to 6.0V OEM Module Spo2 Module ECG Module

Feature

1. Small volume,flexible installment mode,high reliable and accurate test.

2. Excellent reliability and clinical monitoring fuction.

3. It has implemented the monitor of 7 channel ECG, 1channel RESP and2channels temp on the same time.

4. In accordance with function safety design of CE requirements.

5. In accordance with all the ecg/temp monitoring work,

6. Suitable for adult,pediatric and neonate.

7. Single power 5V work,low power consumption design.

Specification

ECG:

Full lead: I, II, III, aVL, aVR, aVF and V

Gain 5mm/mV, 10mm/mV, 20mm/mV and 40mm/mV

Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s

Band width 0.05Hz-100Hz(3dB)

Heart rate:

Scope: 1 times/minute to 300 times/minutes

Accuracy: ±1 time/minute

Variation of heart beat LORENZE drawing:Analysis on heart beat data for the

current 5 minutes with histogram during RR period.

Resp

Chest impedance method or concentration of carbon dioxide at end of respiration

Scope of chest impedance method 0 time/minute – 100 minutes/minute

Precision of chest impedance method 1 time/minute

Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol

Detection scope of respiration rate: 2 times/minute ->60 times/minute

(including baby)

Detection precision of respiration rate: ±1 time/minute

Temp

Single/double path

Type: Vascular/surface temperature

Scope:20℃~50℃

Accuracy±0.2℃

Why Choose Us

DC 3.6V to 6.0V OEM Module Spo2 Module ECG Module

DC 3.6V to 6.0V OEM Module Spo2 Module ECG Module

DC 3.6V to 6.0V OEM Module Spo2 Module ECG Module


Product Tags:

DC 3.6V spo2 module

      

NDIR ECG module

      

DC 6.0V spo2 module

      
Quality DC 3.6V to 6.0V OEM Module Spo2 Module ECG Module for sale

DC 3.6V to 6.0V OEM Module Spo2 Module ECG Module Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shanghai Berry Electronic Tech Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0